| Diagnostic Codes For The Tool Control System (1) |
| For troubleshooting the tool control system, see the procedure with the same CID FMI. |
| CID FMI |
Description |
| CID 145 12 Volt DC Power Supply |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1522 Solenoid Valve for the Number Two Check Valve |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1523 Solenoid Valve for the Number Two Check Valve |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1593 Extend Solenoid Valve for Auxiliary Stem 1 |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1594 Extend Solenoid Valve for Auxiliary Stem 2 |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1595 Extend Solenoid Valve for Auxiliary Stem 3 |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1596 Retract Solenoid Valve for Auxiliary Stem 1 |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1597 Retract Solenoid Valve for Auxiliary Stem 2 |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1598 Retract Solenoid Valve for Auxiliary Stem 3 |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1609 Clench Pressure Sensor |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 04 |
Voltage is below normal or the circuit is shorted low. |
| CID 1615 Solenoid Valve for One-Way Flow or Two-Way Flow |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1657 Left Joystick Slide Control |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 04 |
Voltage is below normal or the circuit is shorted low. |
| FMI 08 |
The signal is abnormal. |
| CID 1658 Right Joystick Slide Control |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 04 |
Voltage is below normal or the circuit is shorted low. |
| FMI 08 |
The signal is abnormal. |
| CID 1665 Solenoid Valve for the Number One Relief Valve |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |
| CID 1666 Solenoid Valve for the Number Two Relief Valve |
| FMI 03 |
Voltage is above normal or the circuit is shorted high. |
| FMI 05 |
Current is below normal or the circuit is open. |
| FMI 06 |
Current is above normal or the circuit is grounded. |