320C and 322C Excavators Attachment Hydraulic System – MID 06A – CID 1593 – FMI 05

Conditions Which Generate This Code:



Illustration 1 g00797160

Schematic of the Extend Solenoid Valve for Auxiliary Stem 1

This diagnostic code is associated with the extend solenoid valve for auxiliary stem 1. This diagnostic code is recorded when the implement ECM reads the current of the solenoid as being below normal. There is an open circuit.

The possible causes of this diagnostic code are listed:

  • The signal circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The implement ECM has failed. This is unlikely.

System Response:

When this diagnostic code occurs, there is no warning on the monitor. The diagnostic code will only be active when the control for the work tool is actuated. An example of this action is pressing the pedal for operating a hammer. The diagnostic code is active when the pedal is pressed. When the pedal is no longer pressed, the diagnostic code is not active, but the code is present in the diagnostic code log (“LOGGED ERROR” screen).

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code is corrected.

Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
  1. Disconnect the solenoid with the diagnostic code from the machine harness.
  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire K856-PU) to wire (K868-BR).
  1. Determine if CID 1593 FMI 05 is present. Check the “ACTIVE ERROR” screen on the monitor.

Expected Result:

The diagnostic code is not active when the jumper wire is installed.

Results:

  • YES – The diagnostic code is not active when the jumper wire is installed. The circuit is correct.

    Repair: The solenoid has failed. Repeat this test step “CHECK THE SOLENOID” in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

  • NO – The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to test step 2.

Test Step 2. CHECK THE HARNESS FOR AN OPEN.

  1. Turn the key start switch and the disconnect switch to the OFF position.
  1. Disconnect the CONN189 and CONN190 machine harness connectors from the implement ECM.
  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire K856-PU) to contact 2 (wire K868-BR).
  1. At the machine harness connector for the ECM, measure the resistance from signal contact CONN190-28 (wire K856-WH) to contact CONN190-28 (wire K868-BR) (return wire).

Expected Result:

The resistance should be less than 5.0 ohms.

Results:

  • OK – The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to test step 3.

  • NOT OK – The resistance is greater than 5.0 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.

    Repair: The open is in wire (K856-PU) or in wire (K868-BR) of the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the harness connectors and clean the contacts of the harness connectors.
  1. Reconnect all harness connectors. Ensure that the connectors are properly seated and ensure that the connections are tight.
  1. Turn the disconnect switch and the key start switch to the ON position.
  1. Enter the service mode on the operator monitor and clear all inactive diagnostic codes.
  1. Operate the machine.
  1. Determine if the CID 1593 FMI 05 is present. Check the “ACTIVE ERROR” screen on the monitor.

Expected Result:

The diagnostic code for the solenoid is NOT present.

Results:

  • YES – The diagnostic code is NOT present. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP

  • NO – The diagnostic code has not been corrected.

    Repair: It is unlikely that the implement ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the implement ECM. See Testing and Adjusting, “Electronic Control Module (ECM) – Replace” for the Tool Control System.

    STOP