“TOOL #1-TOOL #5” of System 5
Refer to Testing and Adjusting, “Work Tool Parameter – Program” for the Tool Control System for instructions on navigating the menus on the display.
The table lists some of the parameters that should be verified for successful operation of the work tool. For this system, parameters that are not shown in the tables do not affect the operation of the work tool.
Default Parameters for “TOOL #1” for System 5 | |||||
---|---|---|---|---|---|
Message Center (Line 3) | Default Values (Line 4) | Range of Values | Increment | Description of Parameter | |
320C, 322C | 325C | ||||
“TOOL#1-001” “Tool Program Name” |
“HAMMER 1PUMP” | “HAMMER 1PUMP” | This is the default name of “TOOL#1”. The default name can be changed. Be sure to use a good descriptive name. When the “Tool Program Name” is entered into ET, the name of the tool must be in all uppercase letters. |
||
“TOOL#1-002” “Maximum Throttle Dial” |
“10” | “10” | Parameter 002 is Enabled when parameter 003 is ON. When Parameter 002 is Enabled and the value of the engine speed dial indicator is Greater than the value of Parameter 002, the engine speed is determined by the value of Parameter 002 when the work tool is activated. When Parameter 002 is Enabled and the value of the engine speed dial indicator is Less than the value of Parameter 002, the engine speed is determined by the value of the engine speed dial indicator when the work tool is activated. Parameter 002 is Disabled when Parameter 003 is OFF. When Parameter 002 is Disabled, the engine speed is determined by the value of the engine speed dial indicator. |
||
“TOOL#1-003” “Throttle Dial Flow Control” |
“ON” | “ON” | When Parameter 003 is ON, Parameter 002 is Enabled. When Parameter 003 is OFF, Parameter 002 is Disabled. |
||
“TOOL#1-004” “Underspeed Enable” |
“ENABLED” | “ENABLED” | “ENABLED” means that the controller maintains the target rpm. “DISABLED” means that the controller provides a constant torque to the pump. Constant torque is used primarily for applications with a magnet. A constant torque maintains a constant rpm for the engine and the generator. |
Blank Table for System 5
Default Parameters for “TOOL#____” for System 5 | |||||
---|---|---|---|---|---|
Message Center (Line 3) | New Default Values (Line 4) | Range of Values | Increment | Comments of Technician | |
320C, 322C | 325C | ||||
“TOOL#-001” | |||||
“TOOL#-002” | |||||
“TOOL#-003” | |||||
“TOOL#-004” | |||||
“TOOL#-005” | |||||
“TOOL#-101” | |||||
“TOOL#-102” | |||||
“TOOL#-103” |