Temperature Sender (Hydraulic Oil)
|
|
|
|
|
|
| Illustration 1 | g00020687 |
|
Temperature Sender (Hydraulic Oil) |
|
The temperature sender for the hydraulic oil connects to the Controller at CONN171-39. The resistance of the sender varies as the temperature changes. The table below lists the resistances:
| Resistances For Temperature Sender (Hydraulic Oil) | |
| Temperature | Resistance |
| 0 °C (32 °F) | 20824 to 25451 Ohms |
| 25 °C (77 °F) | 6134 to 7496 Ohms |
| 35 °C (95 °F) | 3989 to 4875 Ohms |
| 50 °C (122 °F) | 2224 to 2718 Ohms |
| 75 °C (167 °F) | 973 to 1189 Ohms |
| 100 °C (212 °F) | 475 to 522 Ohms |
| 125 °C (257 °F) | 221 to 269 Ohms |
