Page 107
Timer Parameters
Engine Idle Shutdown Timer Reset Enable
Description:
This feature is only available if the Engine Idle Shutdown
System is programmed to Caterpillar. The Engine Idle
Shutdown Timer Reset Enable determines if the Idle
Shutdown Timer can be reset by depressing the Cab
Accelerator Pedal.
When programmed to Enabled (default) the operator
can reset the Idle Shutdown Timer during the driver alert
phase, by depressing the Cab Accelerator Pedal.
Available:
2008 and newer C7, C9, C13 & C15 on-highway engines
Range:
Engine Range
Cat
Default
2008 and newer C7,
C9, C13 & C15
Enabled
Disabled
Enabled
Advantages:
Allows idle to continue based on driver input if
parameter is programmed to Enabled.
Disadvantages:
Fuel consumption is greater if idling.
Recommendations:
✔ Use the default value of Enabled and instruct
the driver to only reset the Idle Shutdown when
necessary.