Page 209
Output Selection
Engine Shutdown Output
Description:
The Engine Shutdown Output parameter is used to
specify the ECM output pin for the Engine Shutdown
Output. This feature is used to shutdown the vehicle
electrical system after the idle timer has expired. The
Engine Shutdown Output comes on after the engine has
been running for more than 3 seconds, and then turns off
when the engine rpm is at least 100 rpm below low idle
for more than 3 seconds.
Available:
C-10, C-12, C-15, C-16, C11, C13, C15 heavy duty engines
and all EPA’07 and newer On-Highway Engines
Range:
Engine Range
Cat
Default
Pre-2007 J1/P1:10, J1/P1:12, J1/P1:13 None
EPA’07 and
newer C7, C9,
C13 & C15
J1/P1: 10, 11,
12, 13, 19, 20
High Side Driver
(2 Amp Output)
None
J1/P1: 29,
30, 31
Low Side Driver
(Sensor Common)
Note: The Engine Shutdown Output is part of the
Caterpillar Multi I/O System. Both High Side (2 Amp
Output) or Low Side (Sensor Common) Drivers can be
programmed. Failure to properly program the Engine
Shutdown Output could cause undesired operation or
damage to chassis components.