Quick Stop Rate (0 = off)
Description:
The Quick Stop Rate parameter value is the threshold at
which a Quick Stop Event (Date, time and snapshot) will
be logged in the ECM memory. The ECM monitors the
rate of change of vehicle speed. If the rate of change is
greater than or equal to the value programmed into the
Quick Stop Rate parameter a Quick Stop Event will be
logged. Quick Stop Rate value is application sensitive,
light loads may require a higher value and heavy loads
a smaller value. If the Quick Stop Rate parameter is
programmed to 0 (zero) the feature is disabled and no
Quick Stop Events will be logged.
Available:
All electronically controlled on-highway engines
covered in this handbook
Range:
Engine
Range
Cat
Default
Minimum Maximum
3126E, C7, C9
0 MPH/Sec
(0 km/h/Sec)
128 MPH/Sec
(205 km/h/Sec)
0
C-10, C-12,
C-15, C-16,
C11, C13, C15
0 MPH/Sec
(0 km/h/Sec)
15 MPH/Sec
(24 km/h/Sec)
0
2007 C7, C9,
C13, C15
3 MPH/Sec
(5 km/h/Sec)
15 MPH/Sec
(24 km/h/Sec)
10 MPH/Sec
(16 km/h/Sec)
Advantages:
All ECM recorded vehicle and engine conditions can
be replayed for 44 seconds before and 15 seconds after
the Quick Stop Event. This data may provide valuable
information on drivetrain component wear.
Disadvantages:
None
Recommendations:
✔ Program a value of 7 MPH/Sec as a starting point.
✔ A value which is too low will cause an excessive
number of events to be recorded.