SEBU8088-06 77
Maintenance Section
Air Inlet Filter - Check
i02574676
Air In let Filter - Check
SMCS Code: 1051-535
Monitor the con
nector contacts of the differential
pressure switch for the air inlet filter. If the differential
pressure rises above 0.15 kPa (0.6 inch of H
2
O) of
water, clean t
he fi lter with a solution of soap and
water. Be sure that the filter is thoroughly dry before
the start-up. Replace the filter, if necessary.
i02676048
Alternator - Inspect
SMCS Code: 1405-040
Caterpillar recommends a scheduled inspection
of the alternator. Inspect the alternator for loose
connections and proper battery charging. Inspect the
ammeter (if equipped) during engine operation in
order to ensure proper battery performance and/or
proper performance of the electrical system. Make
repairs, as required.
Check the alternator and the battery charger for
proper operation. If the batteries are properly
charged, the ammeter reading should be very near
zero. All batteries should be kept charged. The
batteries should be kept warm because temperature
affects the cranking power. If the battery is too cold,
the battery will not crank the engine. The battery will
not crank the engine, even if the engine is warm.
When the engine is not run for long periods of time
or if the engine is run for short periods, the batteries
may not fully charge. A battery with a low charge will
freeze more easily than a battery with a full charge.
i01041029
Batteri
es - Replace
SMCS Code: 1401-510
Batteries give off combustible gases which can
explod
e. A spark can cause the combustible gas-
es to ignite. This can result in severe personal in-
jury or death.
Ensure proper ventilation for batteries that are in
an enclosure. Follow the proper procedures in or-
der to h
elp prevent electrical arcs and/or sparks
near batteries. Do not smoke when batteries are
serviced.
1. Turn the key sta
rt switch to the OFF p osition.
Remove the key and all electrical loads.
2. Turn OFF the ba
ttery charger. Disconnect the
charger.
3. The NEGATIVE “
-” cable connects the NEGATIVE
“-” battery terminal to the ground plane. Disconnect
the cable from the NEGATIVE “-” ba ttery terminal.
4. The POSITIVE “+” cable connects the POSITIVE
“+” battery terminal to the starting motor.
Disconnect t
he cable from the POSITIVE “+”
battery terminal.
Note: Always
recycle a battery. Never discard a
battery. Return used batteries to an appropriate
recycling facility.
5. Remove the used battery.
6. Install the
new ba ttery.
Note: Before connecting the cables, ensure that the
key start sw
itch is OFF.
7. Connect the cable from the starting motor to the
POSITIVE “+
” battery terminal.
8. Connect the cable from the ground plane to the
NEGATIVE “-
” battery terminal.
i00993589
Battery - Rec ycle
SMCS Code: 1401-005; 1401-510; 1401-535;
1401-561; 1401
Always recycle a battery. Never discard a battery.
Always return used batteries to one of the following
locations:
•
A battery supplier
•
An authorized battery collection facility
•
Recycling facility