80 SEBU8088-06
Maintenance Section
Bearing - Inspect
6. Operate the gen
erator for one hour. This will allow
the grease to expand. The expanding grease will
force the excess grease from the cavity. When
the excess gre
ase is forced from the cavity, the
internal pressure will be reduced. The generator
should continue to operate until the grease stops
purging.
7. Stop the engine. Install the plug in the bottom
grease pipe.
Wipe off the excess grease.
8. Install the louver assembly or install the rear plate.
i02230503
Bearing - Inspect
SMCS Code: 4471-040
The following maintenance procedure for generator
bearings should be followed at every major engine
overhaul:
1. Remove the bearing bracket. Inspect the following
items: bracket bore, bearing outer race, and
rolling elements. On standby power units, the
bearing must be inspected and the grease must
be replaced at three year intervals. The sleeve
for the bearing bracket should be inspected for
out of roundness, excessive wear, and a bracket
step that is less than 0.0762 mm (0.0030 inch). If
there is no sleeve for the bearing bracket, inspect
the bore for the bearing bracket. The bearing
should be inspected for damage to the outer race,
severe fretting, and smoothness of operation.
When possible, the bearing elements should be
inspected. Some double shielded ball bearings
prevent visual inspection of the ball bearings.
Other double shielded ball bearings have a
retaining ring. This retaining ring can be removed
in order to allow access for a visual inspection of
the ball bearings.
On two-bearing generators, the front bearing can
only be removed after the hub is removed. In order
to remove the hub, cut off the hub. Pulling the hub
will damage the shaft.
Note: Bearings that are being removed for failure
analysis should not be cut off with a torch.
2. Spherical Roller Bearing should be cleaned and
repacked with 108-8611 Grease. Pack the
bearing and pack the cavity (one-third to one-half
of the volume of the cavity). The bearing should
be filled with 88.8 mL (3 ounces) to 118.4 mL
(4 ounces) of grease. The cavity should be filled
with 118.4 mL (4 ounces) to 148.0 mL (5 ounces)
of grease. Refer to Table 9.
3. All ball bearin
gs should be cleaned. The cavity
of the bracket should be repacked with 2S-3230
Grease. Pack the bearings (one-third to one-half
of the volume o
f the cavity). Refer to Table 9.
To reinstall bearings, heat the bearings to 107 °C
(224.6 °F) fo
r ten minutes. Mount the bearings
on the shaft. To reinstall the hub, heat the hub to
400 °C (752.0 °F) for three hours. Mount the hub
to the shaft.
4. Ensure that the tube that supplies grease to the
bearing is fil
led with grease.
5. Remove the bracket drain plug and operate the
generator fo
r one hour. This will allow the grease
to expand. The expanding grease will force the
excess grease from the cavity. When the excess
grease is fo
rced from the cavity, the internal
pressure will be reduced. The generator should
continue to operate until the grease stops purging.
6. Stop the engine. Install the bracket drain plug.
Wipe off the excess grease.
7. For greasing intervals, follow the recommendations
on the lubrication plate (if equipped) or refer to
Maintenan
ce Schedule, “Bearing - Lubricate”.
Whenever the bearings are greased, repeat Step
5. DO NOT MIX GREASES.