20 SEBU8219-01
Safety Section
Engine Starting
Overspeed shut
down should occur automatically.
If automatic shutdown does not occur, press the
emergency stop button in order to cut the fuel and/or
air to the engi
ne.
Inspect the engine for potential hazards.
Before starting the engine, ensure that no one is on,
underneath, or close to the engine. Ensure that the
area is free o
f personnel.
If equipped, ensure that the lighting system for the
engine is sui
table for the conditions. Ensure that all
lights work properly, if equipped.
All protecti
ve guards and all protective covers must
be installed if the engine must be started in order
to perform service procedures. To help prevent an
accident th
at is caused by parts in rotation, work
around the parts carefully.
Do not bypas
s the automatic shutoff circuits. Do not
disable the automatic shutoff circuits. The circuits are
provided in order to help prevent personal injury. The
circuits a
re also provided in order to help prevent
engine damage.
See the Ser
vice Manual for repairs and for
adjustments.
i02136012
Engine Starting
SMCS Code: 1000
If a warning tag is attached to the engine start switch
or to the controls, DO NOT start the engine or move
the controls. Consult with the person that attached
the warning tag before the engine is started.
All protective guards and all protective covers must
be installed if the engine must be started in order
to perform service procedures. To help prevent an
accident that is caused by parts in rotation, work
around the parts carefully.
If there is a possibility that unburned gas remains in
the exhaust system, refer to the purge procedure in
this Operation and Maintenance Manual, “Engine
Starting” topic in the Operation Section.
Start the engine from the operator’s compartment or
from the engine start switch.
Always start th
eengineaccordingtotheprocedure
that is described in the Operation and Maintenance
Manual, “Engine Starting” topic in the Operation
Section. Know
ing the correct procedure will help to
prevent major damage to the engine components.
Knowing the procedure will also help to prevent
personal inj
ury.
To ensure that the jacket water heater (if equipped)
and/or the lu
be oil heater (if equipped) is working
properly, check the water temperature and the oil
temperature during heater operation.
Engine exhaust contains products of combustion
which can be harmful to your health. Always start the
engine and o
perate the engine in a well ventilated
area. If the engine is started in an enclosed area,
vent the engine exhaust to the outside.
i01964154
Engine Stopping
SMCS Code: 1000
Flash fire may result in personal injury, if
crankcase covers are removed within fifteen
minutes after emergency shut down. Do not
restart engine until cause for shutdown has been
corrected.
To avoid overheating of the engine and accelerated
wear of the engine components, stop the engine
according to this Operation and Maintenance Manual,
“Engine Stopping” topic (Operation Section).
Use the Emergency Stop Button (if equipped)
ONLY in an emergency situation. DO NOT use the
Emergency Stop Button for normal engine stopping.
After an emergency stop, DO NOT start the engine
until the problem that caused the emergency stop
has been corrected.
On the initial start-up of a new engine or an engine
that has been serviced, make provisions to stop the
engine if an overspeed condition occurs. This may be
accomplished by shutting off the fuel supply and/or
the air supply to the engine.