9-16
Status Area
The Data Logger status area monitors the logged data and displays
the time remaining for the current sample. The Time Remaining is
calculated by Cat CCM PC based on the information you enter in
Setup.
Setup Area
The Data Logger setup area allows you to select the sample rate, the
total number of samples taken, and the parameters of the log.
The Log Definition area has two columns: ECM and Group. The
ECM column displays all the ECMs on the Data Link. The group
column displays the selected group name of the parameters being
logged from the corresponding ECM. If the ECM does not have a
selected group, “Not Defined” displays in the group column.
Pushbuttons
The following pushbuttons are available in the Data Logger screen:
•= Edit
•= Clear
•= Start Log/Stop Log
Using Data Logger
Perform the following stepsto start logging:
Step 1 Select how many times you want the sample taken in the
Sample Rate drop-down list. Select either the hour or
minute radio button in the Rate Per area.
Step 2 Select the total number of samples you want taken in the
Total # of Samples drop-down list.
Step 3 Select an ECM from the Log Definition area. Press the
“Edit…” pushbutton. The Select Group dialog box
displays.
Step 4 Select a group from the Select a Group text box. Press
“OK.”
Note: For more information on the Select Group dialog box, see
“Selecting a Group,” section 9, page 5.
Step 5 Press the “Start Log” pushbutton. The Save As dialog
box displays with the default drive.